BFT PHOBOS N BT Instalační manuál Strana 20

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 28
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 19
Terminal Name Description Default Notes
70 COM Safety positive common common
71 STOP Stop command. STOP Overrides all other commands
72 SAFE 1 Safety input #1. Stops operators during opening, reverses on closing
73 FAULT 1 Supervisory circuit for SAFE 1 FAULT Requires opposite relay state from SAFE 1
74 SAFE 2 Safety input #2. BAR Input for safety edges
75 FAULT 2 Supervisory circuit for SAFE 2 FAULT Requires opposite relay state from SAFE 2
PHOT
SAFETY DEVICES
The Thalia board provides one STOP command input, and
two programmable obstruction sensing device inputs, SAFE1
and SAFE2. All 3 safety inputs are N.C. (normally closed)
contacts. Both SAFE 1 and 2 have a device supervision
circuit labeled FAULT. Fault inputs, when enabled, are all
normally open.
Below is a table with the terminal numbers and its
corresponding functions and default values.
Both SAFE1 and SAFE2 can be programmed to perform any of the following functions under the
LOGIC sub-menu:
RELAY COMMON
RELAY N.C.
POWER 24V +
POWER 24V -
EXAMPLE: SAFETY LOOP DETECTOR OR
SAFETY PHOTO BEAM SENSOR WIRING
VALUE FUNCTION DESCRIPTION
000 System reacts to the input in both opening (stops) and closing (reverses) cycles
001 Same as above. Requires the device to be supervised (FAULT active)
002 System reacts to the input only during the opening cycle (stops)
003 Same as above. Requires the device to be supervised (FAULT active)
004 System reacts to the input only during the closing cycle (reverses)
005 Same as above. Requires the device to be supervised (FAULT active)
006 BAR Safety edge input. It reacts in both opening and closing. Stops and partially reverses.
007 BAR TEST Same as above. Requires the device to be supervised (FAULT active)
008 BAR 8K2
PHOT
PHOT TEST
PHOT OP
PHOT OP TEST
PHOT CL
PHOT CL TEST
Safety edge input with EOL resistor as supervision method.
Safety loop detector
Safety photo-beam sensor
PROGRAMMING: LOGIC > SAFE 1 > 004 (PHOT CL)
20